Wednesday, April 29, 2015

UV Cured Adhesive for bonding acylic to paper photo


            UV Cured Adhesive for bonding acylic to paper photo

                                                                            from Tina(hengying@cnhybond.com  0086-18927302778  Skype:hengying11)



Description
HYBOND 313 UV is a single component, medium viscosity, fast curing UV adhesive designed for bonding plastics to glass,metal,plastics(PC, PVC,ABS),Crystal . The product cures in seconds upon exposure to ultraviolet radiation of 365nm

Physical properties
Composition: methacrylate ester
Colour: colourless
Specific weight (g/ml): 1,1
Curing time UV (365 nm): 8 – 15 seconds
Gap to fill: from 0,03 mm to 1,5 mm
Flash point: > 100°C
Shelf life: 1 year

Main Performance(Glass/Metal):

Items
Performance
Type
Hybond 313(1)UV Adhesive
Hybond313(2)UV Adhesive
Color
Clear or yellowish
clear
Viscosity 25 ℃
100 MPa.s
1000cps
Solidify time
About 10s
About 10-15s
Refraction
1.47-1.50
1.47-1.50
Storage
Room temperature, avoid sunlight


Curing properties
For better strength and durability we recommend to clean, degrease and dry surfaces to bond. The polymerisation UV is belonging to the intensity of the UV lamp, to the distance from the UV light source, to the bondline gap and to the light transmittance of the substrate the light shall pass through. We recommend high inensity UV light sources with minimum radiation between 365 nm and 420 nm at 100mW/cm2. curing time may vary according to adhesive gap.

Properties of cured adhesive
* Tensile strength (ASTM D-2095-69): 10 - 14 N/mm²
* Temperature range: -55°C + 120°C
* Refractive index: 1,49
* Light transmittance: > 98%
* Coefficient of thermal expansion: 85 x 10-6 mm/mm/°C
* Dieletric constant ( 25°C 1000 Hz): 4
* Dieletric strength 10-12 KV/mm

Storage
Keep product in a cool and dry room at +28°C. To avoid contaminations do not refill containers with used product. For more information on applications, storage and handling contact hybond Technical Service

7:Storage

Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or greater than 28 °C can adversely affect product properties. Material removed from containers may be contaminated during use. Do not return product to the original container.CNHYBOND Corporation cannot assume responsibility for product which
has been contaminated or stored under conditions other than those previously indicated. If additional information is required, please contact us.

Sunday, April 26, 2015

UV Curing Adhesive for bonding large area to large area of glass


                  UV Curing Adhesive for bonding large area to large area of glass

                                                                                           from Tina(hengying@cnhybond.com  0086-18927302778  Skype:hengying11)




Description
Fast curing, high strength Ultra Violet adhesive, specially designed for bonding small area glass to small area glass, crystal to crystal, even edge to edge, or Three-dimensional bonding between the glass in the manufacturing of glass and crystal table. It’s suitable for safety glass and colorful glass (partly UV radiation absorbing).


Physical properties

302(1)UV
302(2)UV
Composition
methacrylate ester    
methacrylate ester    
Color
colorless
colorless
Viscosity (Brookfield 25°C–mPa.s)
4000±500
100 ±50
Specific weight (g/ml)
1.1  
1,0
Curing time UV (365 nm)
8 – 15 seconds  
8 – 15 seconds  
Gap to fill
from 0.03 mm to 1.5 mm
from 0.03 mm to 1.5 mm
Flash point:
> 100°C  
> 100°C  
Shelf life
1 year    
1 year    




Curing properties

For better strength and durability we recommend to clean, degrease and dry surfaces to bond. The polymerisation UV is belonging to the intensity of the UV lamp, to the distance from the UV light source, to the bondline gap and to the light transmittance of the substrate the light shall pass through. We recommend high inensity UV light sources with minimum radiation between 365 nm and 420 nm at 100mW/cm2. Curing time may vary according to adhesive gap.

Properties of cured adhesive

* Tensile strength (ASTM D-2095-69): 10 - 14 N/mm²
* Temperature range: -55°C + 120°C
* Refractive index: 1.49
* Light transmittance: > 98%
* Coefficient of thermal expansion: 85 x 10-6 mm/mm/°C
* Dieletric constant (25°C 1000 Hz): 4
* Dieletric strength 10-12 KV/mm

Storage

Keep product in a cool and dry room at +28°C. To avoid contaminations do not refill containers with used product. For more information on applications, storage and handling contact hybond Technical Service.


Wednesday, April 22, 2015

UV Glue for bonding glass to metal


                   UV Glue for bonding glass to metal

                                                                   from Tina(hengying@cnhybond.com   0086-18927302778  Skype:hengying11)


Description
Fast curing, high strength Ultra Violet adhesive, specially designed for bonding glass to glass, glass to crystal, glass to metal, even Glass to Aluminum cake and glass to Stainless Steel bonding in the manufacturing of glass and crystal table. It’s suitable for safety glass and color glass (partly UV radiation absorbing).

Physical properties
Composition: methacrylate ester
Color: colorless
Viscosity (Brookfield 25°C–mPa.s): 600 - 1300
Specific weight (g/ml): 1.1 and 1.4
Curing time UV (365 nm): 8 – 15 seconds
Gap to fill: from 0.03 mm to 1.5 mm
Flash point: > 100°C
Shelf life: 1 year

Main Performance(Glass/Metal):

Items
Performance
Type
HYBOND 303(1) UV Adhesive

303(2)UV adhesive
Color
Clear or yellowish
Clear
Viscosity 25℃
650-700 MPa.s
3000±500
Solidify time
About 10s
About 10s
Refraction
1.47-1.50
1.47-1.50
Storage
Room temperature, avoid sunlights


Curing properties
For better strength and durability we recommend to clean, degrease and dry surfaces to bond. The polymerisation UV belongs to the intensity of the UV lamp, to the distance from the UV light source, to the bondline gap and to the light transmittance of the substrate the light shall pass through. We recommend high inensity UV light sources with minimum radiation between 365 nm and 420 nm at 100mW/cm2., curing time may vary according to adhesive gap.

Properties of cured adhesive
* Tensile strength (ASTM D-2095-69): 10 - 14 N/mm²
* Temperature range: -55°C + 120°C
* Refractive index: 1.49
* Light transmittance: > 98%
* Coefficient of thermal expansion: 85 x 10-6 mm/mm/°C
* Dieletric constant (25°C 1000 Hz): 4
* Dieletric strength 10-12 KV/mm

Storage
Keep product in a cool and dry room at +28°C. To avoid contaminations do not refill containers with used product. For more information on applications, storage and handling contact HYBOND Technical Service

Friday, April 17, 2015

UV Adhesive(replace Loctite 3011) for bonding metal to plastic


              UV Adhesive(replace Loctite 3011) for bonding metal to plastic 

                                                             from Tina(hengying@cnhybond.com  0086-18927302778  Skype:hengying11)




Description
HYBOND 313 UV is a single component, medium viscosity, fast curing UV adhesive designed for bonding plastics to glass,metal,plastics(PC, PVC,ABS),Crystal . The product cures in seconds upon exposure to ultraviolet radiation of 365nm

Physical properties
Composition: methacrylate ester
Colour: colourless
Specific weight (g/ml): 1,1
Curing time UV (365 nm): 8 – 15 seconds
Gap to fill: from 0,03 mm to 1,5 mm
Flash point: > 100°C
Shelf life: 1 year

Main Performance(Glass/Metal):

Items
Performance
Type
Hybond 313(1)UV Adhesive
Hybond313(2)UV Adhesive
Color
Clear or yellowish
clear
Viscosity 25 ℃
100 MPa.s
1000cps
Solidify time
About 10s
About 10-15s
Refraction
1.47-1.50
1.47-1.50
Storage
Room temperature, avoid sunlight


Curing properties
For better strength and durability we recommend to clean, degrease and dry surfaces to bond. The polymerisation UV is belonging to the intensity of the UV lamp, to the distance from the UV light source, to the bondline gap and to the light transmittance of the substrate the light shall pass through. We recommend high inensity UV light sources with minimum radiation between 365 nm and 420 nm at 100mW/cm2. curing time may vary according to adhesive gap.

Properties of cured adhesive
* Tensile strength (ASTM D-2095-69): 10 - 14 N/mm²
* Temperature range: -55°C + 120°C
* Refractive index: 1,49
* Light transmittance: > 98%
* Coefficient of thermal expansion: 85 x 10-6 mm/mm/°C
* Dieletric constant ( 25°C 1000 Hz): 4
* Dieletric strength 10-12 KV/mm

Storage
Keep product in a cool and dry room at +28°C. To avoid contaminations do not refill containers with used product. For more information on applications, storage and handling contact hybond Technical Service

Tuesday, April 14, 2015

UV Light Cure Glue for bonding crystal to crystal


             UV Light Cure Glue for bonding crystal to crystal 


                                                                         from Tina(hengying@cnhybond.com   0086-18927302778  Skype:hengying11)                   



Description
Fast curing, high strength Ultra Violet adhesive, specially designed for bonding small area glass to small area glass, crystal to crystal, even edge to edge, or Three-dimensional bonding between the glass in the manufacturing of glass and crystal table. It’s suitable for safety glass and colorful glass (partly UV radiation absorbing).


Physical properties

302(1)UV
302(2)UV
Composition
methacrylate ester    
methacrylate ester    
Color
colorless
colorless
Viscosity (Brookfield 25°C–mPa.s)
4000±500
100 ±50
Specific weight (g/ml)
1.1  
1,0
Curing time UV (365 nm)
8 – 15 seconds  
8 – 15 seconds  
Gap to fill
from 0.03 mm to 1.5 mm
from 0.03 mm to 1.5 mm
Flash point:
> 100°C  
> 100°C  
Shelf life
1 year    
1 year    




Curing properties

For better strength and durability we recommend to clean, degrease and dry surfaces to bond. The polymerisation UV is belonging to the intensity of the UV lamp, to the distance from the UV light source, to the bondline gap and to the light transmittance of the substrate the light shall pass through. We recommend high inensity UV light sources with minimum radiation between 365 nm and 420 nm at 100mW/cm2. Curing time may vary according to adhesive gap.

Properties of cured adhesive

* Tensile strength (ASTM D-2095-69): 10 - 14 N/mm²
* Temperature range: -55°C + 120°C
* Refractive index: 1.49
* Light transmittance: > 98%
* Coefficient of thermal expansion: 85 x 10-6 mm/mm/°C
* Dieletric constant (25°C 1000 Hz): 4
* Dieletric strength 10-12 KV/mm

Storage

Keep product in a cool and dry room at +28°C. To avoid contaminations do not refill containers with used product. For more information on applications, storage and handling contact hybond Technical Service .